Skip to main content
MedVellum
QuestionsVideosPricing

MedVellum

Fellowship exam preparation across every specialty: source-verified topics, questions in every format, and videos.

Product

  • Specialties
  • Questions
  • Videos
  • Exam tools
  • Pricing

Verification & policy

  • Verified register
  • Editorial policy
  • Privacy
  • Terms

Account

  • Sign in
  • Create account
  • Dashboard
  • Account & billing

© 2026 MedVellum. For education only — not a substitute for clinical judgement.

llms.txtPsychiatry LLM catalogSitemap

Anaes VivasMeasurement & monitoring physics

Anaes Vivas · Measurement & monitoring physics

Measurement & monitoring physics — Viva

Clinical viva on oximeter failure modes, capnography, temperature sites, and depth evidence

clinical1 min readVerification in progress

Target exams

ANZCAFRCAABAEDAICFCAIFCA_SA
On this page
Study tools

Target exams

ANZCAFRCAABAEDAICFCAIFCA_SA
Prompt
Fire victim with reassuring saturation; flat capnograph; drifting temperature; depth number in range

Viva Stems

  1. The fire victim's oximeter reads 97% but she is confused. Do you believe the number?
  2. Name the three classic pulse-oximeter limitations and the evidence direction for each.
  3. The capnograph flattens to zero mid-case. Talk me through it.
  4. Where are you measuring temperature, and why that site?
  5. The BIS reads 52 but the patient moves. Who is lying?
  6. The arterial line reads high after repositioning. What do you check?
  7. Which monitor numbers are physics-owned versus convention, and why does the distinction matter?
  8. What are the common exam pitfalls in this topic?
Anaesthesia Pro

Continue reading

You have read the opening of this viva. The complete unit — every section and its primary-source references — is part of the Anaesthesia fellowship library.

Sign in to continueSee pricing
References7ShowHide
  1. [1]Moon K, et al. Pulse Oximetry-A Perioperative Perspective Diagnostics (Basel), 2026.PMID 42351472
  2. [2]León-Valladares D, Barrio-Mateu LA, Cortés-Carmona N, et al. Determining factors of pulse oximetry accuracy: a literature review Rev Clin Esp (Barc), 2024.PMID 38599519
  3. [3]Cotton SA, et al. Do Differences in Skin Pigmentation Affect Detection of Hypoxemia by Pulse Oximetry: A Systematic Review of the Literature Clin Nurs Res, 2025.PMID 41045137
  4. [4]Ishihara T, et al. Time-Based Capnography to Diagnose Airway Obstruction During Lung Lobectomy in a Dog Animals (Basel), 2025.PMID 41375427
  5. [5]Jogie J, et al. Perioperative Temperature Monitoring in Anesthesia: A Review of Current Evidence and Clinical Practice Cureus, 2026.PMID 42147589
  6. [6]Yu H, et al. Depth of anesthesia monitoring: Current evidence, clinical impact, and future directions J Int Med Res, 2026.PMID 42333677
  7. [7]Huang X, et al. Effects of EEG-based monitoring of depth of anesthesia on postoperative delirium, cognitive dysfunction, and long-term neurocognitive outcomes: a meta-analysis Front Med (Lausanne), 2025.PMID 41907691
Anaesthesia Pro

$29/ monthor $279 / year

The complete Anaesthesia library, every exam format, one subscription.

  • Complete library for one chosen specialty
  • Timed MCQ mock exams and spaced review
  • Clinical cases & cross-table vivas
See pricingSign in
PreviousFluid flow: laminar, turbulent and the Reynolds number — VivaMeasurement & monitoring physicsNextPressure and temperature measurement — physics vivaMeasurement & monitoring physics