Anaes Vivas · Measurement & monitoring physics
Data viva — MRI, laser and radiation safety
A Primary physics data viva — read a four-zone MRI suite diagram and an ALARA triangle; describe Zone I to IV access controls and the projectile effect, the magnet quench hazard, the laser airway fire and its prevention, and the ALARA triad (time minimises fluoroscopy, distance inverse square law doubling distance quarters dose, shielding lead aprons and thyroid shields).
On this page
Study tools
Target exams
Stimulus
A diagram shows the four concentric MRI zones of a radiology suite (Zone I the public area, Zone II the screening intake, Zone III the controlled-access staff corridor, Zone IV the scanner room with the quench button on its wall) alongside an ALARA triangle with each side labelled Time, Distance and Shielding. Describe the four zones and the hazard controlled at each boundary, then explain each side of the ALARA triangle and the physical law that underpins the distance principle.