Skip to main content
MedVellum
QuestionsVideosPricing

MedVellum

Fellowship exam preparation across every specialty: source-verified topics, questions in every format, and videos.

Product

  • Specialties
  • Questions
  • Videos
  • Exam tools
  • Pricing

Verification & policy

  • Verified register
  • Editorial policy
  • Privacy
  • Terms

Account

  • Sign in
  • Create account
  • Dashboard
  • Account & billing

© 2026 MedVellum. For education only — not a substitute for clinical judgement.

llms.txtPsychiatry LLM catalogSitemap

Anaes VivasMeasurement & monitoring physics

Anaes Vivas · Measurement & monitoring physics

Clinical viva — pacemaker patient needing diathermy

A clinical viva on diathermy-CIED interaction — pre-operative interrogation and pacing-dependence, choice of bipolar diathermy, reprogramming to asynchronous mode (or magnet), return plate placement, independent pulse monitoring, and post-operative re-interrogation.

clinical2 min readVerification in progress

Target exams

ANZCAFRCAABAEDAIC
On this page
Study tools

Target exams

ANZCAFRCAABAEDAIC
Prompt
A 78-year-old man with a dual-chamber pacemaker (confirmed pacing-dependent on interrogation) is booked for a laparoscopic cholecystectomy in which the surgeon intends to use monopolar diathermy. Walk the examiner through your perioperative device management.

Stimulus

A 78-year-old man with a dual-chamber pacemaker, confirmed pacing-dependent at pre-operative interrogation, presents for a laparoscopic cholecystectomy. The surgeon plans to use monopolar diathermy. Walk the examiner through your perioperative management of his device.

Anaesthesia Pro

Continue reading

You have read the opening of this viva. The complete unit — every section and its primary-source references — is part of the Anaesthesia fellowship library.

Sign in to continueSee pricing
References3ShowHide
  1. [1]Johnson V, et al. [Perioperative complications during transvenous pacemaker and defibrillator implantation]. Herzschrittmachertherapie Elektrophysiol, 2026.PMID 42262440
  2. [5]Fukuoka Y, et al. In Vitro Assessment of 3T MRI Effects on Non-3T-Compatible Cardiac Implantable Electronic Devices. J Cardiovasc Electrophysiol, 2026.PMID 42251742
  3. [8]Hu A, et al. Anesthetic Management for Epicardial Pacemaker Implantation in an Adult Patient With Uncorrected Functional Single Ventricle: Report of One Case. Acta Cardiol Sin, 2026.PMID 42350039
Anaesthesia Pro

$29/ monthor $279 / year

The complete Anaesthesia library, every exam format, one subscription.

  • Complete library for one chosen specialty
  • Timed MCQ mock exams and spaced review
  • Clinical cases & cross-table vivas
See pricingSign in
PreviousEquipment viva — defibrillator and crash cartPerioperative cardiac arrestNextClinical viva — the standards for the basic anaesthetic monitoringMeasurement & monitoring physics