Skip to main content
MedVellum
QuestionsVideosPricing

MedVellum

Fellowship exam preparation across every specialty: source-verified topics, questions in every format, and videos.

Product

  • Specialties
  • Questions
  • Videos
  • Exam tools
  • Pricing

Verification & policy

  • Verified register
  • Editorial policy
  • Privacy
  • Terms

Account

  • Sign in
  • Create account
  • Dashboard
  • Account & billing

© 2026 MedVellum. For education only — not a substitute for clinical judgement.

llms.txtPsychiatry LLM catalogSitemap

Anaes VivasMeasurement & monitoring physics

Anaes Vivas · Measurement & monitoring physics

Data viva — the capnogram waveform

A Primary data viva — infrared measurement of exhaled CO2 with numeric and waveform display; flat oesophageal trace; relentlessly rising EtCO2 in malignant hyperthermia; EtCO2 10 mmHg or less after 20 minutes of CPR predicts death.

data2 min readVerification in progress

Target exams

ANZCAFRCAABAEDAIC
On this page
Study tools

Target exams

ANZCAFRCAABAEDAIC
Prompt
Three capnogram strips are shown: (1) a flat trace at zero over several breaths during attempted intubation; (2) a relentlessly rising end-tidal CO2 unresponsive to increased ventilation; (3) a low end-tidal value during cardiac arrest. Interpret each trace and state the physical principle behind the monitor.

Stimulus

Three capnogram strips are shown: (1) a flat trace at zero over several breaths during attempted intubation; (2) a relentlessly rising end-tidal CO2 unresponsive to increased ventilation; (3) a low end-tidal value during cardiac arrest. Interpret each trace and state the physical principle behind the monitor.[2]

Anaesthesia Pro

Continue reading

You have read the opening of this viva. The complete unit — every section and its primary-source references — is part of the Anaesthesia fellowship library.

Sign in to continueSee pricing
References6ShowHide
  1. [1]Jaffe MB Infrared measurement of carbon dioxide in the human breath: "breathe-through" devices from Tyndall to the present day. Anesth Analg, 2008.PMID 18713902
  2. [2]Long B, Koyfman A, et al. Capnography in the Emergency Department: A Review of Uses, Waveforms, and Limitations. J Emerg Med, 2017.PMID 28993038
  3. [3]Groeneveld NTA, et al. Recognition of esophageal intubation in Dutch prehospital emergency medical services using capnography analysis: a retrospective cohort study. Resuscitation, 2026.PMID 41548748
  4. [4]Singh A, Kataria S, John G, et al. Diastolic blood pressure and end-tidal carbon dioxide during adult ICU cardiopulmonary resuscitation: association with return of spontaneous circulation. Resuscitation, 2026.PMID 42331277
  5. [5]Levine RL, Wayne MA, et al. End-tidal carbon dioxide and outcome of out-of-hospital cardiac arrest. N Engl J Med, 1997.PMID 9233867
  6. [6]Ali SZ, Taguchi A, et al. Malignant hyperthermia. Best Pract Res Clin Anaesthesiol, 2003.PMID 14661655
Anaesthesia Pro

$29/ monthor $279 / year

The complete Anaesthesia library, every exam format, one subscription.

  • Complete library for one chosen specialty
  • Timed MCQ mock exams and spaced review
  • Clinical cases & cross-table vivas
See pricingSign in
PreviousData viva — the 2x2 contingency table and diagnostic test performanceMeasurement & monitoring physicsNextData viva — the confounder triangle and the funnel plotMeasurement & monitoring physics